HOME Mode S | S03KH-T2 | S3.6KH-T2 | S4KH-T2 | S5KH-T2 | S6KH-T2 | ||
PV input | Max. PV array power | 5500wh STC | 6180wh STC | 6500wh STC | 7500wh STC | 9000wh STC | |
Max. input voltage | 550V | ||||||
MPP voltage range / rated input voltage | 40V to 530V/380V | ||||||
Min. input voltage / start voltage | 40V/50V | ||||||
No. of independent MPPT trackers / strings per MPPT input | 2/(1/1) | ||||||
Max. input current per MPP tracker | 16A | ||||||
Max. short-circuit current per MPP tracker | 20A | ||||||
Battery input | Battery type | LiFePO4 | |||||
Total capacity | 5kwh | 10kwh | 15kwh | 20kwh | 25kwh | 30kwh | |
Number of battery boxes | 1 | 2 | 3 | 4 | 5 | 6 | |
Nominal battery voltage | 51.2V | ||||||
Max. charging current / Max. discharging current | 100A/100A | ||||||
AC output | AC voltage range / Nominal AC voltage | 180 V to 280 V / 230 V | |||||
Rated AC grid frequency | 50 Hz / 60 Hz | ||||||
AC grid frequency range | 50 Hz±5Hz / 60 Hz±5Hz | ||||||
Rated active power | 3000W | 3680W | 4000W | 5000W | 6000W | ||
Rated apparent power | 3000VA | 3680VA | 4000VA | 5000VA | 6000VA | ||
Max. apparent power | 3000VA | 3680VA | 4000VA | 5000VA | 6000VA | ||
Rated grid output Current (@230V) | 13.1A | 16A | 17.4A | 21.7A | 26.1A | ||
Max. grid output current | 13.6A | 16A | 18.2A | 22.7A | 27.1A | ||
Harmonics THDi (@ Nominal power) | < 3% | ||||||
AC input | Rated grid voltage | a.c. 230V | |||||
Rated grid frequency | 50Hz /60H | ||||||
Rated apparent power | 6000 VA | ||||||
Max. input apparent power from grid | 6000 VA | ||||||
Rated input current from grid | a.c. 26.1A | ||||||
Max. input current from grid | a.c. 27.3 A | ||||||
EPS output | Nominal output voltage | 230 V | |||||
Nominal output frequency | 50Hz /60H | ||||||
Rated apparent power | 5000 VA | ||||||
Max. output apparent power | 5000 VA | ||||||
Peak output apparent power | 7500 VA, 10s | ||||||
Rated Current (@230V) | 21.7 A | ||||||
Max. output current | 21.7 A | ||||||
Max. switch time | ≤10 ms | ||||||
Output THDi (@ Linear load) | <3% | ||||||
Efficiency | MPPT efficiency | 99.90% | |||||
Euro efficiency / Max. efficiency | 97% /97.6% | ||||||
Max. battery to load efficiency | 94.70% | ||||||
Safety protection | DC-side disconnection device | ● | |||||
PV string- / Battery input reverse polarity protection | ●/● | ||||||
All-pole sensitive residual current monitoring unit | ● | ||||||
Anti-islanding protection | ● | ||||||
Ground fault protection | ● | ||||||
AC output over current / short circuit current protection | ●/● | ||||||
AC over voltage protection | ● | ||||||
Protection class (as per IEC 62109-1) / overvoltage category (as per IEC 62109-1) |
I / AC: III; DC: II | ||||||
General data | Power factor at rated power / adjustable displacement | ≥0.99 / 0.8 leading to 0.8 lagging | |||||
Dimensions (W / H / D) | 550/220/998 | 550/220/1415 | 1200/220/1415 | 1200/220/1415 | 1200/220/1415 | ||
Device weight | ≈84KG | ≈131KG | ≈182KG | ≈232KG | ≈282KG | ||
Operating temperature range | -25°C……+60°C | ||||||
Noise emissions | < 30 dB(A) | ||||||
Standby consumption | < 10 W | ||||||
Cooling concept | Natural convection | ||||||
Degree of protection (as per IEC 60529 | IP65 | ||||||
Climatic category (according to IEC 60721-3-4) | 4K4H | ||||||
Max. permissible value for relative humidity (non-condensing) | 0~95% | ||||||
Max. operating altitude | 4000m (>3000m power derating) | ||||||
Features | User interface | LED & App | |||||
Communication method | RS485 / CAN/Wifi | ||||||
Integrated power control / Zero export control | ●/● |